Item talk:Q59229
From geokb
{
"USGS Publications Warehouse": { "schema": { "@context": "https://schema.org", "@type": "CreativeWork", "additionalType": "USGS Numbered Series", "name": "U.S. Geological Survey Noble Gas Laboratory\u2019s standard operating procedures for the measurement of dissolved gas in water samples", "identifier": [ { "@type": "PropertyValue", "propertyID": "USGS Publications Warehouse IndexID", "value": "tm5A11", "url": "https://pubs.usgs.gov/publication/tm5A11" }, { "@type": "PropertyValue", "propertyID": "USGS Publications Warehouse Internal ID", "value": 70155229 }, { "@type": "PropertyValue", "propertyID": "DOI", "value": "10.3133/tm5A11", "url": "https://doi.org/10.3133/tm5A11" } ], "inLanguage": "en", "isPartOf": [ { "@type": "CreativeWorkSeries", "name": "Techniques and Methods" } ], "datePublished": "2015", "dateModified": "2015-08-12", "abstract": "This report addresses the standard operating procedures used by the U.S. Geological Survey\u2019s Noble Gas Laboratory in Denver, Colorado, U.S.A., for the measurement of dissolved gases (methane, nitrogen, oxygen, and carbon dioxide) and noble gas isotopes (helium-3, helium-4, neon-20, neon-21, neon-22, argon-36, argon-38, argon-40, kryton-84, krypton-86, xenon-103, and xenon-132) dissolved in water. A synopsis of the instrumentation used, procedures followed, calibration practices, standards used, and a quality assurance and quality control program is presented. The report outlines the day-to-day operation of the Residual Gas Analyzer Model 200, Mass Analyzer Products Model 215\u201350, and ultralow vacuum extraction line along with the sample handling procedures, noble gas extraction and purification, instrument measurement procedures, instrumental data acquisition, and calculations for the conversion of raw data from the mass spectrometer into noble gas concentrations per unit mass of water analyzed. Techniques for the preparation of artificial dissolved gas standards are detailed and coupled to a quality assurance and quality control program to present the accuracy of the procedures used in the laboratory.", "description": "vi, 21 p.", "publisher": { "@type": "Organization", "name": "U.S. Geological Survey" }, "author": [ { "@type": "Person", "name": "Hunt, Andrew G. ahunt@usgs.gov", "givenName": "Andrew G.", "familyName": "Hunt", "email": "ahunt@usgs.gov", "identifier": { "@type": "PropertyValue", "propertyID": "ORCID", "value": "0000-0002-3810-8610", "url": "https://orcid.org/0000-0002-3810-8610" }, "affiliation": [ { "@type": "Organization", "name": "Crustal Geophysics and Geochemistry Science Center", "url": "https://www.usgs.gov/centers/geology-energy-and-minerals-science-center" } ] } ], "funder": [ { "@type": "Organization", "name": "Crustal Geophysics and Geochemistry Science Center", "url": "https://www.usgs.gov/centers/geology-energy-and-minerals-science-center" } ] } }
}